Origin 65 ADCP is an innovative, flexible and high-performance device designed for customers requiring long-range current profiles from deep sites. Combining a novel and market-changing acoustic design, integrated modem, Pressure Inverted Echo Sounder (PIES) and mechanical release, and advanced software, this device revolutionises what is possible with a deep water ADCP.

Key operational parameters of the Origin 65 instrument are shown below.

Parameter Specification
Operating frequency 62.5 kHz
Maximum profiling range 800+ m
Minimum blanking distance 12 m
Minimum cell size 120 mm
Maximum number of cells 2500
Maximum ping rate 1 Hz (4 beams)
Ambiguity limit Up to ±2 m/s or 3.75 m/s user selectable
Depth rating555 5,000 m operational

See the Origin 65 datasheet for detailed features and specifications.

 